PDJ-3000A
Availability: | |
---|---|
Quantity: | |
Specifications
8.4 Inch Color TFT display
Suitablefor adult, pediatric and neonatalpa
Multi-parameter like: ECG PR TEMP NIBP SPO2
Audibleand visual alarms with adjustable alarm ranges
Networkable with central monitoring
Powerful data management and storage capa
ECG Lead type: 5-lead
Input:RA; LA; RL; LL; V
Sweepspeed: 12.5mm/s, 25mm/s, 50mm/s
Accuracy:± 1 bpm or ±1%, whichever isgreater
Protection:Withstand 4000VAC/50Hz voltagein isolation against electrosurgical anddefibrillatio
S-Tdetection: YES, Arrhythmia analysis:YES
Alarm:YES, audible and visual alarm, alarmevents recallable
NIBPMethod: Oscillometry
Operationmodes: Manual/Automatic/STAT
Measurementunit: mmHg/KPa selectable
Measurementtypes: Systolic, Diastolic,Mean
Over-pressureprotection: YES
SpO2Measurement range: 0-100%
Accuracy:±2%digit (70~100%) 0~69%unspecified
ECG
Leadtype:5-lea
Input:RA;LA; RL; LL; V
Sweepspeed:12.5mm/s, 25mm/s, 50mm/s
Accuracy:±1 bpm or ±1%, whichever is greater
Protection:Withstand4000VAC/50Hz voltage in isolation against electrosurgical anddefibrillation
S-Tdetection:YES, Arrhythmia analysis: YES
Alarm:YES,audible and visual alarm, alarm events recallable
NIBP
Method:Oscillometry
Operationmodes:Manual/Automatic/STA
Measurementunit:mmHg/KPa selectable
Measurementtypes:Systolic, Diastolic, Mean
Over-pressureprotection:YES
SpO2
Measurementrange:0-100%
Accuracy:±2%digit(70~100%) 0~69% unspecified
Standard Configuration
ECG,NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery, thermal printer
Specifications
8.4 Inch Color TFT display
Suitablefor adult, pediatric and neonatalpa
Multi-parameter like: ECG PR TEMP NIBP SPO2
Audibleand visual alarms with adjustable alarm ranges
Networkable with central monitoring
Powerful data management and storage capa
ECG Lead type: 5-lead
Input:RA; LA; RL; LL; V
Sweepspeed: 12.5mm/s, 25mm/s, 50mm/s
Accuracy:± 1 bpm or ±1%, whichever isgreater
Protection:Withstand 4000VAC/50Hz voltagein isolation against electrosurgical anddefibrillatio
S-Tdetection: YES, Arrhythmia analysis:YES
Alarm:YES, audible and visual alarm, alarmevents recallable
NIBPMethod: Oscillometry
Operationmodes: Manual/Automatic/STAT
Measurementunit: mmHg/KPa selectable
Measurementtypes: Systolic, Diastolic,Mean
Over-pressureprotection: YES
SpO2Measurement range: 0-100%
Accuracy:±2%digit (70~100%) 0~69%unspecified
ECG
Leadtype:5-lea
Input:RA;LA; RL; LL; V
Sweepspeed:12.5mm/s, 25mm/s, 50mm/s
Accuracy:±1 bpm or ±1%, whichever is greater
Protection:Withstand4000VAC/50Hz voltage in isolation against electrosurgical anddefibrillation
S-Tdetection:YES, Arrhythmia analysis: YES
Alarm:YES,audible and visual alarm, alarm events recallable
NIBP
Method:Oscillometry
Operationmodes:Manual/Automatic/STA
Measurementunit:mmHg/KPa selectable
Measurementtypes:Systolic, Diastolic, Mean
Over-pressureprotection:YES
SpO2
Measurementrange:0-100%
Accuracy:±2%digit(70~100%) 0~69% unspecified
Standard Configuration
ECG,NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery, thermal printer